Consulting
Engineers of
Ontario

Markham
Waxers

Environmental
Abatement Council
of Ontario

|


LEAD
ABATEMENT |
Lead can be found in interior and exterior paints or in plumbing as
lead pipes or lead solder on copper pipes. The presence or absence of lead in a building
may have many implications.

video
Lead Abatemen
Project at CFB Borden
Realplayer
28.8k | 56k
(download RealPlayer)

Lead Abatement
Project at Barrie
Armouries
Realplayer
28.8 | 56k |
The
value of a property may be greatly reduced due to the presence of lead. Dangers associated
with lead dust from renovation and demolition activities in older buildings and the high
costs for lead clean-up or removal by recognized professionals must be realized and passed
on to your clients. Lead is now being placed in the same group as asbestos and urea
formaldehyde with regards to reducing the value of a property. Lead, once identified,
becomes a health hazard to contractors and a potential future liability for property
owners and the architect responsible for the project.
As a licensed
and responsible professional you must be aware of and identify the presence or absence of
these materials when dealing with building retrofits. Failure to advise your client(s) or
contractors working on a project of the presence of hazardous materials in and/or on a
property may present you with potential future liabilities. It is your obligation to
protect the interests of your client(s), the health and safety of workers, and the natural
environment.
Restoration
Environmental Contractors will arrange an independent consultant for hazardous materials
and other potential environmental concerns on residential, commercial and industrial
properties. Each assessment includes sampling of all suspected hazardous materials,
confirmatory laboratory analysis and complete reporting of all findings. We can also
complete specifications and tender packages for any required remedial activities and
perform project management services.
All
environmental consultants and environmental engineers are licensed, have errors and
omissions insurance and pollution, asbestos and environmental coverage. |
LEAD ABATEMENT AND HEAVY METAL CLEANUPS |
Restoration Environmental Contractors has over 100,000 hours
of Lead Cleanup experience that can be utilized on your Lead Project.
We have successfully completed more lead projects than all
the other contractors combined in Canada.
Some
of Canadian clients include: Northern Telecom, Mitsubishi Electronics, Canadian Tire
Corporation etc.
However,
many of our Lead Projects are also U.S. clients such as: Allied Signal, Certified Brakes,
Bendix HVS, Textron Inc. Duracell etc..
View our
entire client list. |
SCOPE OF WORK AND SPECIFICATIONS |
All work will conform to the Occupational Health & Safety Act, the
Ministry of Labour Guidelines, and the Ministry of Environment's Guideliness for Cleanup
of Soils, Industrial Commercial Sites.
Prior
to any work commencing, a number of swab samples must be taken from the areas to be
cleaned. An independent consultant must select various locations in the cleanup area.
All swab test
analyses must be supplied to Restoration Consultants, as results must be available for:
The Ministry of Labour - Lead Contamination
Brochure
The Ministry of Environment
Personnel - under
the Occupational Health & Safety Act all personnel on site must be informed of the
contaminants on site.
|
TRAINING |
No untrained persons will be allowed on the site once site remedial
procedures have commenced. All personnel must be properly trained in Asbestos, WHMIS and
Lead Abatement. Prior to cleanup, personnel will participate in a review of all
contaminants found on the site, including training in proper handling, packaging, and
preparation for disposal of Dust, Heany Metal, and/or Chemical contaminants on site.
Positive
Air Pressured Respirators will be used, and personnel will require Respirator fit testing
off all respirators. All suits, gloves and eye protection equipment will be approved for
use with contaminants on site. Training will cover procedures for decontamination,
showering and cleansing of personnel and protective equipment. Personnel will also receive
instruction in all necessary procedures to protect personal health of themselves and
co-workers.
If
lead is contained in the swab samples, all personnel must have blood samples taken before
starting and after completion of the project. |
CONTAMINATED DUST CLEANUP PROCEDURES |
No untrained persons will be allowed on the site once site remedial
procedures have commenced. All personnel must be properly trained in Asbestos, WHMIS and
Lead Abatement. Prior to cleanup, personnel will participate in a review of all
contaminants found on the site, including training in proper handling, packaging, and
preparation for disposal of Dust, Heany Metal, and/or Chemical contaminants on site.
Positive
Air Pressured Respirators will be used, and personnel will require Respirator fit testing
off all respirators. All suits, gloves and eye protection equipment will be approved for
use with contaminants on site. Training will cover procedures for decontamination,
showering and cleansing of personnel and protective equipment. Personnel will also receive
instruction in all necessary procedures to protect personal health of themselves and
co-workers.
If
lead is contained in the swab samples, all personnel must have blood samples taken before
starting and after completion of the project.
A
Decontamination Structure will be installed with change room, clean room, shower
facilities, and dirty room. Hot and cold water will be made available.
All electrical
service will be connected to Temporary
Ground Fault Electrical Panels
HEPA Negative Air Filtering Units will be installed
at various locations in the area where dust cleaning procedures are being performed.
HEPA Vacuums will only be used on site
for the collection of dust contaminants from surface areas. |
CLEANUP PROCEDURES: SCOPE OF WORK - TYPE 3 |
Areas that are not included in this contract will be sealed off.
Install
decontamination structure so all personnel must enter and leave through air lock
system.
HEPA Vacuum ceilings, pipes, light
fixtures, conduits, structural beams, I-beams, walls, ledges and floors.
Remove
surface contaminated dust that can or will become airborne. Remove and
clean the air handling plastic ductwork for disposal.
All
Ventilation and Heating equipment (this is not included in our quotation) must be
cleaned and serviced, all filters changed and handed over to us for disposal preparation
and packaging.
All
surfaces of lights, windows, and heating equipment will be wet wiped and washed by
hand. Contaminated water will be collected and saved for proper disposal.
A
light acid wash will be used to neutralize affected surfaces.
HEPA Filters will be installed on all
showers and water supply, to be changed daily.
A
very light water misting will be used
during removal of surface dust for dust settling.
An
Encapsulant Latex Air Glue will be sprayed on surfaces throughout
contaminated area, if required. All floors are covered with plastic. All surfaces which
contain dirt or solid grease are sprayed only after surface dust has been removed.
A cleanup and
disinfection of the test area will be completed immediately after commencement. This
area will have had two swab samples analyzed.
All
waste, contaminated dust, suits, rags and water will be placed in waste receptors to be collected
for pickup by a licensed Ministry of Environment Transport/Hauler to an approved
designated disposal site. A generator number and registration by the Ministry of
Environment is required.A cleanup and
disinfection of the test area will be completed immediately after commencement. This
area will have had two swab samples analyzed.
Disposal
and pickup costs are not included in our quotation. Laidlaw and
Republic are two haulers and disposal firms which are very competitive. The arrangements
made for disposal and haulage as well as the preparation, packaging, bagging, and drum
supply for the waste is included. |
SAMPLE CHARTS PROVIDED |
Charts will give the parameters of the contaminants, the averages
prior ro cleanup, after cleanup and percentage of cleanup efficiency. The area selected
usually contains a very high level of contaminated dust. |
GENERAL NOTES |
Only the minimum amount of water should be used. All water will be
collected, and NO water will be discharged without the consent of consultant and prior
testing and analysis, to ensure that it conforms with required sanitary sewage bylaws. The
showers of the decontamination structure will have approved MOE and OSHA approved HEPA Filtering equipment.
Only
qualified personnel
approved by consultant and/or contractor will have building access one the project
commences. Anyone entering the building must have proof of Asbestos and WHMIS training
program, and will require hard-toed boots, safety goggles, respirator training, and
hard-hat.
Power
washing and steam cleaning are not recommended due to the possibility of water runoff and
seepage into concrete, floors, ground water and water table, sewers, and possible ground
soil contamination. |
Copyright © 1999 - 2007,
Restoration Environmental Contractors.
All rights reserved.
|